{"product_id":"rich-solar-rs-cbk1301a-off-grid-solar-kit","title":"Rich Solar Complete Off-Grid Solar Kit | 30 x MEGA 410 | 13,000W 120\/240V Output | 48VDC","description":"\u003cstyle\u003e\n  .gg-pdp-y3 {\n    font-family: Arial, sans-serif;\n    color: #001B30;\n    line-height: 1.65;\n    max-width: 1180px;\n    margin: 0 auto;\n  }\n\n  .gg-pdp-y3 * {\n    box-sizing: border-box;\n  }\n\n  .gg-pdp-y3 h2,\n  .gg-pdp-y3 h3,\n  .gg-pdp-y3 h4 {\n    color: #001B30;\n    margin: 0 0 10px;\n    line-height: 1.2;\n  }\n\n  .gg-pdp-y3 p {\n    margin: 0 0 14px;\n    color: #18344a;\n  }\n\n  .gg-pdp-y3 ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n\n  .gg-pdp-y3 li {\n    margin: 7px 0;\n    color: #18344a;\n  }\n\n  .gg-pdp-y3-hero {\n    position: relative;\n    overflow: hidden;\n    border-radius: 24px;\n    padding: 34px;\n    margin: 0 0 22px;\n    background:\n      radial-gradient(circle at 85% 15%, rgba(41, 196, 255, .22), transparent 34%),\n      radial-gradient(circle at 12% 85%, rgba(255, 255, 255, .12), transparent 28%),\n      linear-gradient(135deg, #001B30 0%, #073A5A 58%, #0B6F8F 100%);\n    color: #fff;\n  }\n\n  .gg-pdp-y3-hero h2 {\n    color: #fff;\n    font-size: clamp(26px, 3.6vw, 42px);\n    max-width: 880px;\n  }\n\n  .gg-pdp-y3-hero p {\n    color: rgba(255, 255, 255, .92);\n    max-width: 830px;\n    font-size: 17px;\n  }\n\n  .gg-pdp-y3-eyebrow {\n    display: inline-flex;\n    align-items: center;\n    background: rgba(255, 255, 255, .14);\n    border: 1px solid rgba(255, 255, 255, .25);\n    border-radius: 999px;\n    padding: 7px 13px;\n    font-size: 12px;\n    font-weight: 800;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin-bottom: 14px;\n    color: #fff;\n  }\n\n  .gg-pdp-y3-tags {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 10px;\n    margin-top: 18px;\n  }\n\n  .gg-pdp-y3-tag {\n    display: inline-flex;\n    border-radius: 999px;\n    padding: 8px 12px;\n    background: rgba(255, 255, 255, .12);\n    border: 1px solid rgba(255, 255, 255, .18);\n    color: #fff;\n    font-size: 13px;\n    font-weight: 700;\n  }\n\n  .gg-pdp-y3-grid {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: 14px;\n    margin: 0 0 20px;\n  }\n\n  .gg-pdp-y3-card {\n    background: #fff;\n    border: 1px solid #dbe8ef;\n    border-radius: 20px;\n    padding: 20px;\n    box-shadow: 0 12px 30px rgba(0, 27, 48, .08);\n  }\n\n  .gg-pdp-y3-icon {\n    width: 42px;\n    height: 42px;\n    display: inline-flex;\n    align-items: center;\n    justify-content: center;\n    border-radius: 14px;\n    margin-bottom: 12px;\n    background: #eef8fb;\n    color: #0B6F8F;\n    font-size: 21px;\n    font-weight: 900;\n  }\n\n  .gg-pdp-y3-section {\n    background: #f7fbfd;\n    border: 1px solid #dbe8ef;\n    border-radius: 22px;\n    padding: 24px;\n    margin: 0 0 18px;\n  }\n\n  .gg-pdp-y3-split {\n    display: grid;\n    grid-template-columns: 1.05fr .95fr;\n    gap: 16px;\n    align-items: stretch;\n  }\n\n  .gg-pdp-y3-panel {\n    background: #fff;\n    border: 1px solid #e3eef3;\n    border-radius: 18px;\n    padding: 18px;\n  }\n\n  .gg-pdp-y3-note {\n    border-left: 4px solid #0B6F8F;\n    background: #eef8fb;\n    border-radius: 16px;\n    padding: 15px 17px;\n    margin-top: 14px;\n    color: #18344a;\n  }\n\n  .gg-pdp-y3-feature-row {\n    display: grid;\n    grid-template-columns: 1fr 1fr;\n    gap: 16px;\n    align-items: center;\n    margin: 0 0 18px;\n  }\n\n  .gg-pdp-y3-feature-row.reverse {\n    direction: rtl;\n  }\n\n  .gg-pdp-y3-feature-row.reverse \u003e * {\n    direction: ltr;\n  }\n\n  .gg-pdp-y3-feature-row img {\n    width: 100%;\n    border-radius: 18px;\n    border: 1px solid #dbe8ef;\n    display: block;\n    object-fit: cover;\n    aspect-ratio: 4 \/ 3;\n  }\n\n  .gg-pdp-y3-feature-copy {\n    padding: 8px 4px;\n  }\n\n  .gg-pdp-y3-feature-copy h3 {\n    font-size: 20px;\n    margin-bottom: 4px;\n  }\n\n  .gg-pdp-y3-feature-copy .component-sub {\n    font-size: 13px;\n    font-weight: 700;\n    color: #0B6F8F;\n    text-transform: uppercase;\n    letter-spacing: .06em;\n    margin-bottom: 10px;\n  }\n\n  \/* Kit inclusion list *\/\n  .gg-pdp-y3-kit-box {\n    background: #fff;\n    border: 2px solid #0B6F8F;\n    border-radius: 22px;\n    padding: 24px 28px;\n    margin: 0 0 20px;\n  }\n\n  .gg-pdp-y3-kit-box h3 {\n    color: #0B6F8F;\n    margin-bottom: 16px;\n    font-size: 20px;\n  }\n\n  .gg-pdp-y3-kit-items {\n    display: grid;\n    grid-template-columns: repeat(2, 1fr);\n    gap: 10px 24px;\n  }\n\n  .gg-pdp-y3-kit-item {\n    display: flex;\n    align-items: flex-start;\n    gap: 10px;\n    color: #18344a;\n    font-size: 15px;\n    line-height: 1.5;\n  }\n\n  .gg-pdp-y3-kit-item-icon {\n    width: 28px;\n    height: 28px;\n    flex-shrink: 0;\n    background: #eef8fb;\n    border-radius: 8px;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-size: 14px;\n    color: #0B6F8F;\n    font-weight: 900;\n    margin-top: 2px;\n  }\n\n  \/* System sizing stats *\/\n  .gg-pdp-y3-stat-grid {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 12px;\n    margin: 0 0 20px;\n  }\n\n  .gg-pdp-y3-stat-card {\n    background: #fff;\n    border: 1px solid #dbe8ef;\n    border-radius: 16px;\n    padding: 16px 12px;\n    text-align: center;\n  }\n\n  .gg-pdp-y3-stat-card .stat-value {\n    font-size: 22px;\n    font-weight: 900;\n    color: #0B6F8F;\n    margin-bottom: 4px;\n    line-height: 1.1;\n  }\n\n  .gg-pdp-y3-stat-card .stat-label {\n    font-size: 12px;\n    color: #18344a;\n    text-transform: uppercase;\n    letter-spacing: .04em;\n    font-weight: 700;\n  }\n\n  .gg-pdp-y3-spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 13.5px;\n  }\n\n  .gg-pdp-y3-spec-table tr {\n    border-bottom: 1px solid #e3eef3;\n  }\n\n  .gg-pdp-y3-spec-table tr:last-child {\n    border-bottom: none;\n  }\n\n  .gg-pdp-y3-spec-table td {\n    padding: 8px 10px;\n    color: #18344a;\n    vertical-align: top;\n  }\n\n  .gg-pdp-y3-spec-table td:first-child {\n    font-weight: 700;\n    color: #001B30;\n    width: 50%;\n  }\n\n  .gg-pdp-y3-spec-table tr:nth-child(even) {\n    background: #f7fbfd;\n  }\n\n  @media (max-width: 860px) {\n    .gg-pdp-y3-hero {\n      padding: 24px;\n      border-radius: 20px;\n    }\n\n    .gg-pdp-y3-grid,\n    .gg-pdp-y3-split,\n    .gg-pdp-y3-feature-row,\n    .gg-pdp-y3-kit-items {\n      grid-template-columns: 1fr;\n    }\n\n    .gg-pdp-y3-stat-grid {\n      grid-template-columns: repeat(2, 1fr);\n    }\n\n    .gg-pdp-y3-feature-row.reverse {\n      direction: ltr;\n    }\n\n    .gg-pdp-y3-card,\n    .gg-pdp-y3-section,\n    .gg-pdp-y3-panel,\n    .gg-pdp-y3-kit-box {\n      padding: 17px;\n    }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"gg-pdp-y3\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003csection class=\"gg-pdp-y3-hero\"\u003e\n    \u003cspan class=\"gg-pdp-y3-eyebrow\"\u003eRich Solar • Complete Off-Grid System • 48VDC\u003c\/span\u003e\n    \u003ch2\u003eComplete Off-Grid Solar Kit — 30 × MEGA 410, 13,000W 120\/240V Output, 48VDC\u003c\/h2\u003e\n    \u003cp\u003e\n      A fully engineered, whole-home capable off-grid solar system built around 30 MEGA 410 monocrystalline panels (12.3kW array), dual 6.5kW NOVA hybrid inverters running in parallel for a combined 13,000W of 120\/240V output, and four ALPHA 5 PRO server-rack lithium batteries delivering over 20kWh of usable storage. Every major wiring component — disconnects, busbars, extension cables — is included and sized for the system, along with a free battery rack to house the entire battery bank.\n    \u003c\/p\u003e\n    \u003cdiv class=\"gg-pdp-y3-tags\"\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003e12.3kW Solar Array\u003c\/span\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003e13,000W 120\/240V Output\u003c\/span\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003e20.48kWh Battery Storage\u003c\/span\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003e48VDC System\u003c\/span\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003eDual Parallel Inverters\u003c\/span\u003e\n      \u003cspan class=\"gg-pdp-y3-tag\"\u003eFree Battery Rack Included\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- HERO IMAGE --\u003e\n  \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n    \u003cimg src=\"https:\/\/richsolar.com\/cdn\/shop\/files\/Complete_Off-Grid_Solar_Kit_13_000W_120_240V_Output_48VDC_-_410W_x_30.jpg?v=1725258866\u0026amp;width=1200\" alt=\"Rich Solar complete off-grid solar kit 30 MEGA 410 panels dual inverters ALPHA 5 PRO batteries\" loading=\"lazy\" style=\"width: 100%; border-radius: 20px; border: 1px solid #dbe8ef; display: block; object-fit: cover; max-height: 480px;\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SYSTEM SIZING AT A GLANCE --\u003e\n  \u003cdiv class=\"gg-pdp-y3-stat-grid\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-stat-card\"\u003e\n      \u003cdiv class=\"stat-value\"\u003e12.3kW\u003c\/div\u003e\n      \u003cdiv class=\"stat-label\"\u003eSolar Array (30 Panels)\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-stat-card\"\u003e\n      \u003cdiv class=\"stat-value\"\u003e13,000W\u003c\/div\u003e\n      \u003cdiv class=\"stat-label\"\u003e120\/240V AC Output\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-stat-card\"\u003e\n      \u003cdiv class=\"stat-value\"\u003e20.48kWh\u003c\/div\u003e\n      \u003cdiv class=\"stat-label\"\u003eUsable Battery Storage\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-stat-card\"\u003e\n      \u003cdiv class=\"stat-value\"\u003e48VDC\u003c\/div\u003e\n      \u003cdiv class=\"stat-label\"\u003eSystem Architecture\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- KIT CONTENTS --\u003e\n  \u003cdiv class=\"gg-pdp-y3-kit-box\"\u003e\n    \u003ch3\u003eComplete Kit Contents\u003c\/h3\u003e\n    \u003cdiv class=\"gg-pdp-y3-kit-items\"\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e☀\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e30 × MEGA 410 Solar Panels (RS-M410)\u003c\/strong\u003e — 410W monocrystalline, 12.3kW total array\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e⚡\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e2 × NOVA 6548 Inverters (RS-H6548)\u003c\/strong\u003e — 6,500W 48V off-grid hybrid, parallel-capable\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e🔋\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e4 × ALPHA 5 PRO Batteries (RS-B5121P)\u003c\/strong\u003e — 5.12kWh each, 51.2V 100Ah LiFePO4 server rack format\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e⏚\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e2 × Solar PV DC Quick Disconnect Switch (RS-i4)\u003c\/strong\u003e — array-side disconnect safety\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e⊞\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e2 × 600A Busbar\u003c\/strong\u003e — high-current battery and inverter interconnection\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e⎓\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e4 × 4-Foot 2\/0 AWG Wire Set\u003c\/strong\u003e — heavy-gauge battery-to-inverter interconnects\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e↔\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e8 × 50-Foot 10AWG Solar Extension Cables (RS-50102)\u003c\/strong\u003e — array wiring runs\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e↔\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e4 × 30-Foot 10AWG Solar Extension Cables (RS-30102-T2)\u003c\/strong\u003e — additional array wiring runs\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-kit-item\"\u003e\n        \u003cdiv class=\"gg-pdp-y3-kit-item-icon\"\u003e🎁\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003e1 × Free Battery Rack\u003c\/strong\u003e — houses the full 4-battery ALPHA 5 PRO bank\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 3-CARD HIGHLIGHTS --\u003e\n  \u003cdiv class=\"gg-pdp-y3-grid\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-card\"\u003e\n      \u003cdiv class=\"gg-pdp-y3-icon\"\u003e⚡\u003c\/div\u003e\n      \u003ch3\u003e13,000W Through Two Parallel Inverters\u003c\/h3\u003e\n      \u003cp\u003e\n        Two NOVA 6548 inverters operating in parallel deliver a combined 13,000W of 120\/240V split-phase output — enough to run full-home appliance loads, including 240V equipment like well pumps, electric ranges, or workshop tools, not just 120V circuits.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-card\"\u003e\n      \u003cdiv class=\"gg-pdp-y3-icon\"\u003e🔋\u003c\/div\u003e\n      \u003ch3\u003e20.48kWh in a Server-Rack Format\u003c\/h3\u003e\n      \u003cp\u003e\n        Four ALPHA 5 PRO batteries provide 20.48kWh of total energy storage in a stackable server-rack configuration, with the included free battery rack keeping the bank organized, ventilated, and easy to expand later.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-card\"\u003e\n      \u003cdiv class=\"gg-pdp-y3-icon\"\u003e☀\u003c\/div\u003e\n      \u003ch3\u003e12.3kW Array with 10-Busbar MEGA 410 Panels\u003c\/h3\u003e\n      \u003cp\u003e\n        Thirty 410W monocrystalline panels using a 10-busbar Mono PERC cell design deliver a 12.3kW array capable of meaningfully recharging a 20kWh battery bank across a full sunny day in most regions.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- PRODUCT OVERVIEW --\u003e\n  \u003csection class=\"gg-pdp-y3-section\"\u003e\n    \u003ch3\u003eSystem Overview\u003c\/h3\u003e\n    \u003cp\u003e\n      This complete off-grid solar kit is engineered as a matched system rather than a loose collection of compatible parts — every component is sized to work together as a 48VDC architecture capable of supplying full 120\/240V split-phase power to a home, cabin, workshop, or off-grid property. The 12.3kW solar array, dual parallel inverters, and 20.48kWh battery bank are proportioned so that the array can realistically recharge the battery bank within a day of good sun, and the inverter pair can carry meaningful whole-property loads without the array or batteries becoming a bottleneck.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The two NOVA 6548 inverters operate in parallel for a combined 13,000W continuous output with 2x surge capacity for five seconds — enough headroom for motor-start loads like well pumps, air conditioners, and power tools that draw a brief inrush current well above their running wattage. Each inverter includes a built-in MPPT solar charger, smart AC charging, Wi-Fi monitoring through Rich Solar's app, and a detachable LCD control module — giving you both local panel access and remote system visibility.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      Battery storage comes from four ALPHA 5 PRO server-format LiFePO4 batteries, each rated for 5.12kWh, 100A continuous charge\/discharge current, and a sophisticated onboard BMS with overcharge, over-discharge, and overcurrent protection. The included battery rack organizes all four units into a single stacked enclosure, and the platform is rated to expand up to 15 batteries in parallel if you need to grow capacity well beyond what ships in this kit.\n    \u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- COMPONENT 1: PANELS --\u003e\n  \u003csection class=\"gg-pdp-y3-feature-row\"\u003e\n    \u003cimg src=\"https:\/\/richsolar.com\/cdn\/shop\/files\/Complete-Off-Grid-Solar-Kit-Mega-410.jpg?v=1747343858\u0026amp;width=700\" alt=\"Rich Solar MEGA 410 solar panel array component of complete off-grid kit\" loading=\"lazy\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-feature-copy\"\u003e\n      \u003cdiv class=\"component-sub\"\u003eComponent 1 of 3 — Solar Array\u003c\/div\u003e\n      \u003ch3\u003e30 × MEGA 410 — 12.3kW Monocrystalline Array\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003e410W Per Panel, 24V Class:\u003c\/strong\u003e Each panel operates at 31.3V Vmp and 37.5V Voc, suited to wiring in series strings for the inverters' MPPT input range.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e10-Busbar Mono PERC Cells:\u003c\/strong\u003e Improves output consistency and low-light performance versus older cell technology, with strong morning, evening, and overcast-day generation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAnodized Aluminum Frame + AR-Coated Tempered Glass:\u003c\/strong\u003e Built for permanent outdoor installation, with anti-reflective coating improving light capture across the day.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e1500VDC Max System Voltage:\u003c\/strong\u003e Supports long series strings for large array configurations like this 30-panel system.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e25-Year Output \/ 10-Year Workmanship Warranty:\u003c\/strong\u003e The same warranty structure used across Rich Solar's MEGA rigid panel lineup.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e45.2 lb, 67.8 × 44.7 × 1.2 in Per Panel:\u003c\/strong\u003e Standard full-size rigid panel dimensions — plan rooftop, ground-mount, or rack space accordingly for 30 units.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- COMPONENT 2: BATTERIES --\u003e\n  \u003csection class=\"gg-pdp-y3-feature-row reverse\"\u003e\n    \u003cimg src=\"https:\/\/richsolar.com\/cdn\/shop\/files\/4x-5120Wh-Server-ALPHA-5-PRO.jpg?v=1747344958\u0026amp;width=700\" alt=\"Rich Solar ALPHA 5 PRO server rack lithium battery component of complete off-grid kit\" loading=\"lazy\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-feature-copy\"\u003e\n      \u003cdiv class=\"component-sub\"\u003eComponent 2 of 3 — Battery Bank\u003c\/div\u003e\n      \u003ch3\u003e4 × ALPHA 5 PRO — 20.48kWh Server-Format Storage\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003e5.12kWh Per Unit, 51.2V 100Ah LiFePO4:\u003c\/strong\u003e Four units combine for 20.48kWh of total nominal storage in a stackable server-rack form factor.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e100A Continuous Charge \u0026amp; Discharge:\u003c\/strong\u003e Each battery supports sustained high-current charge and discharge, matched to the demands of a multi-kW inverter setup.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e7,000 Deep Cycle Life, 10-Year Lifespan:\u003c\/strong\u003e A long-duty-cycle design intended for daily off-grid charge\/discharge cycling over a decade of service.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUL1973 \u0026amp; UL9540A Certified:\u003c\/strong\u003e Independently certified for battery safety and energy storage system safety standards.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSophisticated BMS Protection:\u003c\/strong\u003e Onboard battery management handles overcharge, over-discharge, overcurrent, and short-circuit protection automatically.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExpandable to 15 Units in Parallel:\u003c\/strong\u003e This kit ships with 4 batteries, but the platform supports significant future expansion if your storage needs grow.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIncluded Battery Rack:\u003c\/strong\u003e The free rack (27.5\"L × 27.5\"W × 44.1\"H, 196.2 lb) houses and organizes the full 4-battery bank in one stacked enclosure.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- COMPONENT 3: INVERTERS --\u003e\n  \u003csection class=\"gg-pdp-y3-feature-row\"\u003e\n    \u003cimg src=\"https:\/\/richsolar.com\/cdn\/shop\/files\/2x-6.5kW-Inverter.jpg?v=1747344814\u0026amp;width=700\" alt=\"Rich Solar NOVA 6548 hybrid inverter component of complete off-grid kit\" loading=\"lazy\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-feature-copy\"\u003e\n      \u003cdiv class=\"component-sub\"\u003eComponent 3 of 3 — Inverters\u003c\/div\u003e\n      \u003ch3\u003e2 × NOVA 6548 — 13,000W Combined Hybrid Output\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003e6,500W Each, Parallel-Rated to 6 Units:\u003c\/strong\u003e This kit uses 2 of the 6 units the platform supports in parallel — combined 13,000W continuous with 2x rated power surge for 5 seconds.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt-In MPPT Solar Charging:\u003c\/strong\u003e Each inverter accepts up to 4000W of PV input (8000W combined across both units) with a 90-450VDC MPPT operating range.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePure Sine Wave Output, 91% Peak Efficiency:\u003c\/strong\u003e Clean AC power suitable for sensitive electronics as well as standard household appliances.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eWi-Fi Monitoring + Detachable LCD:\u003c\/strong\u003e Monitor and configure the system remotely via app, or locally through the detachable LCD control module.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e120A Max Solar \u0026amp; AC Charge Current:\u003c\/strong\u003e Configurable charging priority and current limits via the LCD control panel based on your specific setup.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUL 1741 Certified by TÜV:\u003c\/strong\u003e Independently certified to U.S. grid-interactive and stand-alone inverter safety standards.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e3-Year Warranty:\u003c\/strong\u003e Shorter coverage window than the panels or batteries — factor this into your overall system warranty planning.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- DETAILED SPECS --\u003e\n  \u003csection class=\"gg-pdp-y3-section\"\u003e\n    \u003cdiv class=\"gg-pdp-y3-split\"\u003e\n      \u003cdiv class=\"gg-pdp-y3-panel\"\u003e\n        \u003ch3\u003eMEGA 410 Panel Specs\u003c\/h3\u003e\n        \u003ctable class=\"gg-pdp-y3-spec-table\"\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax Power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e410W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eVmp \/ Imp\u003c\/td\u003e\n\u003ctd\u003e31.3V \/ 13.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eVoc \/ Isc\u003c\/td\u003e\n\u003ctd\u003e37.5V \/ 13.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax System Voltage\u003c\/td\u003e\n\u003ctd\u003e1500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax Series Fuse\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°F to 185°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight \/ Dimensions\u003c\/td\u003e\n\u003ctd\u003e45.2 lb \/ 67.8 × 44.7 × 1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e25-yr output \/ 10-yr workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/table\u003e\n        \u003ch3 style=\"margin-top: 18px;\"\u003eNOVA 6548 Inverter Specs\u003c\/h3\u003e\n        \u003ctable class=\"gg-pdp-y3-spec-table\"\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRated Power (Per Unit)\u003c\/td\u003e\n\u003ctd\u003e6500VA \/ 6500W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e48VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax PV Input (Per Unit)\u003c\/td\u003e\n\u003ctd\u003e4000W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90–450VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax Solar\/AC Charge Current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e91%\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eParallel Capability\u003c\/td\u003e\n\u003ctd\u003eUp to 6 units\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL 1741 (TÜV)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"gg-pdp-y3-panel\"\u003e\n        \u003ch3\u003eALPHA 5 PRO Battery Specs\u003c\/h3\u003e\n        \u003ctable class=\"gg-pdp-y3-spec-table\"\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNominal Voltage \/ Capacity\u003c\/td\u003e\n\u003ctd\u003e51.2V \/ 100Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eEnergy Per Unit\u003c\/td\u003e\n\u003ctd\u003e5120Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax Charge\/Discharge Current\u003c\/td\u003e\n\u003ctd\u003e100A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCycle Life\u003c\/td\u003e\n\u003ctd\u003e7,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMax Parallel Expansion\u003c\/td\u003e\n\u003ctd\u003e15 units\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBattery Weight\u003c\/td\u003e\n\u003ctd\u003e99.2 lb each\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 \/ RS232 \/ CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL1973, UL9540A, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/table\u003e\n        \u003ch3 style=\"margin-top: 18px;\"\u003eBest Uses\u003c\/h3\u003e\n        \u003cul\u003e\n          \u003cli\u003eOff-grid homes requiring full 120\/240V appliance support\u003c\/li\u003e\n          \u003cli\u003eCabin and rural property primary power systems\u003c\/li\u003e\n          \u003cli\u003eWorkshop, barn, or agricultural off-grid power\u003c\/li\u003e\n          \u003cli\u003eProperties needing well pump or 240V equipment support\u003c\/li\u003e\n          \u003cli\u003eSystems anticipating future battery bank expansion\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"gg-pdp-y3-note\"\u003e\n      \u003cstrong\u003eSystem design note:\u003c\/strong\u003e This kit is also available with alternative panel configurations (38 × 335W, 32 × 400W) or with no panels included if you're sourcing your own array. Professional installation is strongly recommended for a system at this scale and voltage — 48VDC battery wiring, the included 600A busbars, and the 2\/0 AWG interconnects involve current levels that require correct sizing, torque, and protection to install safely. Consult a licensed installer familiar with off-grid hybrid inverter systems for site-specific design, permitting, and commissioning.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\u003csection class=\"gg-product-learning-links\" data-gg-learning-links=\"20261002\"\u003e\u003ch2\u003ePlan the solar array\u003c\/h2\u003e\n\u003cp\u003eOur \u003ca href=\"\/blogs\/news\/how-to-choose-the-right-solar-panels-for-your-home-rv-or-cabin\"\u003esolar panel selection guide\u003c\/a\u003e helps compare panel types and ratings. For installation planning, the \u003ca href=\"\/blogs\/news\/series-vs-parallel-solar-panel-wiring-guide\"\u003eseries versus parallel wiring guide\u003c\/a\u003e explains the electrical difference between wiring panels in series and parallel.\u003c\/p\u003e\u003c\/section\u003e","brand":"RICH SOLAR","offers":[{"title":"Default Title","offer_id":52511759302937,"sku":"RS-CBK1301A","price":20999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1005\/7318\/4281\/files\/Complete_Off-Grid_Solar_Kit_13_000W_120_240V_Output_48VDC_-_410W_x_30_838f8374-9baf-4cc8-834b-0a280490d927.jpg?v=1781210335","url":"https:\/\/gridgetaway.com\/products\/rich-solar-rs-cbk1301a-off-grid-solar-kit","provider":"Grid Getaway","version":"1.0","type":"link"}