Renogy 12in 4 AWG Copper Battery Interconnect Cable for 5/16 In Lugs 1 / 5
Renogy

Renogy 12in 4 AWG Copper Battery Interconnect Cable for 5/16 In Lugs Renogy 12in 4 AWG Copper Battery Interconnect Cable for 5/16 In Lugs

SKU: RNG-BATTERYCB-12IN-4-G1-US

Brand Renogy In Stock
$12.99 In Stock
No sales tax collected at checkout where applicable.
5% off Save 5% on eligible items Copy this code and apply it at checkout when eligible. Code: GET5
Extra 5% offUse GET5 at checkout

Applies to eligible items.

Estimated delivery Calculating current delivery window…
Secure checkoutProtected payment Free shippingView shipping policy Eligible returnsView return policy Authorized dealerRenogy warranty
Free shippingAuthorized dealer

Will this run what you need?

Check your setup with our team.

Shipping & returnsDelivery details, return eligibility & fees

Shipping
Free shipping. Check the availability and delivery information above for your selected option.

Returns

Approval is required. The 30-day window covers eligible products that have not been used or installed, with their original packaging and supplied contents retained.

For non-defective returns, you pay return shipping and may incur restocking charges of up to 20%. Processing fees of 3–4% are not refundable. The full policy explains exceptions and how to request a return.

Secure checkout · Protected payment
Authorized dealer · Renogy warranty

No sales tax collected at checkout where applicable.

Need help choosing? Find the right setup for you. Talk it through with our team, or size your system with the Power Planner. Call 1-844-747-6767 Open Power Planner

Quantity

Your selection

Renogy 12in 4 AWG Copper Battery Interconnect Cable for 5/16 In Lugs

In Stock
Renogy 12in 4 AWG Copper Battery Interconnect Cable for 5/16 In Lugs
Quantity$12.99 each
1

Copper Battery Interconnect Cable for 5/16 in Lugs — 12In 4AWG

Build compatible series or parallel battery connections with a Renogy copper interconnect cable fitted with 5/16-inch M8 tin-plated copper lugs. The cable is described by Renogy as TUV-listed, UV-resistant and waterproof, with heat-shrink tubing for abrasion resistance and electrical safety in suitable off-grid installations.

Series Connection

Connect the negative terminal of one battery to the positive terminal of the next to increase system voltage while keeping amp-hour capacity the same.

Renogy battery cable series connection example

Parallel Connection

Connect matching negative terminals together and matching positive terminals together to increase capacity while maintaining system voltage.

Renogy battery cable parallel connection example

Series/Parallel Connection

Combine series and parallel wiring to increase both voltage and available capacity in a suitable multi-battery system.

Renogy battery cable series-parallel connection example
Renogy battery interconnect cable RV applicationRV application iconRenogy battery interconnect cable marine applicationMarine application iconRenogy battery interconnect cable camping applicationCamping application iconRenogy battery interconnect cable outdoor applicationOutdoor application iconRenogy battery interconnect cable cabin applicationCabin application iconRenogy battery interconnect cable truck applicationTruck application icon
Package Includes
1 Renogy Battery Interconnect Cables
Renogy 12in 4AWG Battery Interconnect Cables
Selected variant SKU RNG-BATTERYCB-12IN-4-G1-US
Length 12in
AWG 4
Material 100% copper cable with tin coat
Terminal 5/16inn battery rings at both ends
Stranding Class K 30 gauge bare copper
Voltage 600/1000 V
Temperature 221°F Dry, 167°F Wet
100% copper cable with a tin coated Terminal: 5/16In battery rings at both ends
Stranding: Class K 30 gauge bare copper Voltage: 600/1000 V
Length: 14In AWG: 4
Length: 16In AWG: 4
Accessories 1-year material warranty

Frequently Asked Questions

Clear answers to common questions about this product, setup, compatibility, and use.

Will I receive a red-and-black pair of 12-inch battery interconnect cables? No. This product page is for one 12-inch 4 AWG interconnect cable. A typical parallel battery connection needs two equal-length conductors, so order the required quantity and identify polarity correctly during installation. How can I confirm the 5/16-inch rings will fit my battery terminals? Check the battery's threaded stud or bolt diameter rather than judging from the terminal cover. Both cable ends use 5/16-inch rings; do not drill out a lug or force it onto incompatible hardware because that can weaken the connection. Can this single interconnect be used to wire batteries in either series or parallel? Yes, it can serve as a battery-to-battery interconnect in a correctly designed series or parallel bank. Parallel wiring normally needs matching positive and negative paths of equal length, while every bank must follow the battery manufacturer's connection limits. Is 4 AWG automatically large enough for any inverter connected to the battery bank? No. Gauge alone does not establish suitability. Size the complete circuit from continuous current, surge current, total conductor length, allowable voltage drop, insulation rating, ambient temperature, terminal rating, and the required fuse or breaker. What construction helps this short Renogy cable handle battery-bank service? Renogy uses flexible Class K copper strands, tin-coated 5/16-inch terminals, heat shrink, and UV-resistant waterproof insulation. Those features improve routing and corrosion resistance, but the cable still needs clean contact surfaces, correct torque, strain relief, and periodic inspection.