Renogy Battery Shunt 300 Remote Battery Monitoring 1 / 9
Renogy

Renogy Battery Shunt 300 Remote Battery Monitoring Renogy Battery Shunt 300 Remote Battery Monitoring

SKU: RSHST-B02P300-G1-US

Brand Renogy In Stock
$120.99 In Stock
No sales tax collected at checkout where applicable.
5% off Save 5% on eligible items Copy this code and apply it at checkout when eligible. Code: GET5
Extra 5% offUse GET5 at checkout

Applies to eligible items.

Estimated delivery Calculating current delivery window…
Secure checkoutProtected payment Free shippingView shipping policy Eligible returnsView return policy Authorized dealerRenogy warranty
Free shippingAuthorized dealer

Will this run what you need?

Check your setup with our team.

Shipping & returnsDelivery details, return eligibility & fees

Shipping
Free shipping. Check the availability and delivery information above for your selected option.

Returns

Approval is required. The 30-day window covers eligible products that have not been used or installed, with their original packaging and supplied contents retained.

For non-defective returns, you pay return shipping and may incur restocking charges of up to 20%. Processing fees of 3–4% are not refundable. The full policy explains exceptions and how to request a return.

Secure checkout · Protected payment
Authorized dealer · Renogy warranty

No sales tax collected at checkout where applicable.

Key features
  • -Compatible with various batteries Lead Acid, LFP, Li-ion, and Ni-MH.
  • Battery Capacity 1 - 6500Ah
  • Weight 0.57lb (260g )
Need help choosing? Find the right setup for you. Talk it through with our team, or size your system with the Power Planner. Call 1-844-747-6767 Open Power Planner

Quantity

Your selection

Renogy Battery Shunt 300 Remote Battery Monitoring

In Stock
Renogy Battery Shunt 300 Remote Battery Monitoring
Quantity$120.99 each
1

RENOGY Battery Shunt 300

Monitor battery charge status and system data through compatible Renogy ONE Core and DC Home App integrations using the Battery Shunt 300.

Renogy Battery Shunt 300 feature overview

Check Battery Charging Level Anywhere

Access precise battery monitoring data through compatible Renogy ONE Core and DC Home App connectivity.

Renogy Battery Shunt 300 monitoring with mobile display
Renogy Battery Shunt 300 construction features

Track Battery Performance Over Time

In addition to real-time monitoring, Battery Shunt 300 records historical data through compatible Renogy ONE Core and DC Home App connections to support system decisions.

Renogy Battery Shunt 300 data monitoring

Compatible With Multiple Battery Types

The Shunt 300 is compatible with suitable starter and main batteries, including lead-acid, lithium iron phosphate, lithium-ion and nickel-metal hybrid battery types.

Renogy Battery Shunt 300 battery compatibility

Certified Performance

Battery Shunt 300 is built for dependable monitoring performance across compatible power-system setups.

Renogy Battery Shunt 300 certified performance

Battery Temperature Sensor

Battery temperature sensing supports safe, efficient and data-informed system monitoring in suitable applications.

Renogy Battery Shunt 300 temperature sensor

Effortless Installation in 5 Minutes

The shunt can be positioned on top of a suitable battery or secured to a wall, with protective covers intended to help keep connection points secure.

Renogy Battery Shunt 300 mounting

Fast Connection in 4 Steps

Pairing with compatible Renogy ONE Core and DC Home App equipment supports a real-time data display experience.

Renogy Battery Shunt 300 connection flow

Quick Setup

Simple initial configuration helps users begin monitoring a compatible battery system.

Renogy Battery Shunt 300 setup screen
Battery Shunt 300 Remote Battery Monitoring
Package Includes
1 Battery Shunt 300 Remote Battery Monitoring
Temperature Sensor
Package Includes
1 Temperature Sensor
1.5m (4.92ft) B1/B2 Wires
Package Includes
1 1.5m (4.92ft) B1/B2 Wires
22AWG 1m (3.28ft) B1/B2 Wires
Package Includes
1 22AWG 1m (3.28ft) B1/B2 Wires
Quick Guide
Package Includes
1 Quick Guide
Mounting Screws
Package Includes
1 Mounting Screws
Package Includes
1 Battery Shunt 300
Package Includes
2 B+ Wires (1 m) (22 AWG)
Package Includes
1 Temperature Sensor (1.5 m)
Battery Shunt 300
Selected variant SKU RSHST-B02P300-G1-US
Electrical Data
Model Name RSHST-B02P300-G1
Power Supply 8 - 120 VDC
Power Consumption <0.1W
Communication Bluetooth LE and BLE Mesh
Max Continuous Current 300A
Max Peak Current 500A <10s
Current Accuracy ±1%
Current Resolution 0.01A
Battery Capacity 1 - 6500Ah
Voltage Input Range 8V to 120V DC
Voltage Input Resolution 10mV
Temperature Sensor Range -20℃~80℃
Temperature Sensor Accuracy ±1%
Environmental Data
Operating Temperature 14°F to 122°F / -10°C to 50°C
Operating Humidity 0% to 95% RH
Operating Altitude Less Than 2000m Above Sea Level
Mechanical Specifications
Installation Surface Mounting
Battery Connection M10 Bolts
Dimensions 5.27 x 3.82 x 1.22 in / 134 x 97 x 31 mm
Weight 0.57 lb / 260g
Warranty
Warranty 1-Year Material and Workmanship Warranty
Certifications
Certifications CE, FCC ID, IC ID, RCM, TSCA, RoHS, UN38.3, TELEC
-Compatible with various batteries Lead Acid, LFP, Li-ion, and Ni-MH.

Frequently Asked Questions

Clear answers to common questions about this product, setup, compatibility, and use.

1.In DC Home or Renogy ONE, the current is shown as negative when charging and positive when discharging. Inspect for reverse contact on B- or Pterminals. 2. Incorrect temperature reading Confirm the Battery Temperature Sensor is properly installed. 3. Incorrect SOC reading The battery capacity decreases as the charging and discharging cycles increase.Re-configure the “Rated Battery Ah” to the capacity when the battery is fully charged. 4.Inaccurate sampling precision in large-current scenarios Elevated ambient temperatures can affect sampling accuracy. Ensure proper ventilation for the shunt and remove the upper cover if needed. 5.What should I do if my Battery Shunt 300 is showing only discharging readings? If you notice that your Battery Shunt 300 displays only discharging readings after installation, with the readings staying at zero, please follow these steps: 1.Remove Battery Shunt from both Renogy One Core and DC Home. 2. Uninstall the DC Home app and install a new DC Home app. 3. To avoid potential conflicts, turn off your phone before proceeding. 4.Set Renogy One Core to pairing mode and reset the Battery Shunt. 5.Pair Renogy One Core and Battery Shunt 300, then turn on your phone. 6.Activate pairing in DC Home; you will see a link, not the Battery Shunt 300 readings. However, this link is pairing Battery Shunt 300 and Renogy One Core with DC Home. 7. Pair this link. By following these steps,you can resolve the issue, and the Battery Shunt 300 readings displayed correctly. If the issue persists, it's recommended to contact Renogy's technical support for further assistance. 6.Why does the SOC alarm parameter on my Battery Shunt reset to 50% in Renogy Core One settings? If you're experiencing an issue where the State of Charge (SOC) alarm parameter you set for the Battery Shunt in Renogy Core One settings resets to 50% after a short period, follow these steps for troubleshooting: 1.Turn off the power to the Battery Shunt 300. 2.Delete the Battery Shunt 300 from the Renogy One Core settings. 3.Turn the power back on for the Battery Shunt 300. 4.Add the Battery Shunt 300 back to the Renogy One Core. 5.Refer to the user manual for the Battery Shunt 300 and follow the provided instructions for setting up the SOC alarm parameter. By following these troubleshooting steps, you can resolve the issue of the SOC alarm parameter resetting to the default value.If the issue persists, it's recommended to contact Renogy's technical support for further assistance. 7.What should I do if my Battery Shunt 300 can connect to my phone but not to Renogy One Core? If your Battery Shunt successfully connects to your phone but faces issues connecting to Renogy One Core, consider the following steps: 1.Check Renogy One Core Firmware 2.Reset the Battery Shunt 300:Press and hold the reset button on the Battery Shunt for 5 seconds until the Bluetooth light turns off. 3.Connection Steps:On the Renogy One Core, click "Add Device" and scan for the Battery Shunt 300.Once detected, the Battery Shunt's Bluetooth light should stay solid. By following these troubleshooting steps, you can resolve issues related to Battery Shunt connectivity with the Renogy One Core. If problems persist, contact Renogy's technical support for further assistance. 8.Battery charge percentage doesn’t show and the Consumed Ah reading is way off. If you encounter abnormal data readings on the Battery Shunt 300, follow these troubleshooting steps: 1.Power off the Battery Shunt 300 and restart it. 2.Perform charge and discharge cycles on the battery pack connected to the Battery Shunt 300. 3.After the restart and cycling, check if the consumed Ampere-Hours (AH) reading returns to normal. If the issue persists after the above steps, please contact our support team for further assistance. 9.The Battery Shunt 300 doesn't have programming options for lithium or lead-acid batteries. Can it not be programmed for lithium or lead-acid batteries? Battery Shunt 300 does not differentiate between battery types. Its calculations are based on current and voltage. During the initial connection, it will prompt you to input the battery capacity. It can also be manually calibrated. After fully charging the battery, set the current SOC to 100% in the settings.While specific programming for different battery types isn't available, these settings and manual adjustments ensure precise monitoring and control. 10.Can the Battery Shunt 300 handle battery banks larger than 300A? The 300A specification of the Battery Shunt represents its maximum capacity rather than indicating a limitation based on battery bank size. It is not restricted to use only with 300A battery banks. To ensure compatibility, calculate the actual maximum continuous current in your circuit, and the Battery Shunt 300 should be suitable for monitoring larger battery banks. Which equipment is verified to work with the Renogy RSHST-B02P300-G1-US? The manufacturer explicitly lists Lead Acid, LFP, Li-ion, and Ni-MH.. Other models are not established as compatible by this evidence.