Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W 1 / 1
Victron

Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W

SKU: PMP122305102

Brand Victron In Stock
$1,088.00 In Stock
No sales tax collected at checkout where applicable.
5% off Save 5% on eligible items Copy this code and apply it at checkout when eligible. Code: GET5
Extra 5% offUse GET5 at checkout

Applies to eligible items.

Estimated delivery Calculating current delivery window…
Secure checkoutProtected payment Free shippingView shipping policy Eligible returnsView return policy Authorized dealerVictron warranty
Free shippingAuthorized dealer

Will this run what you need?

Check your setup with our team.

Shipping & returnsDelivery details, return eligibility & fees

Shipping
Free shipping. Check the availability and delivery information above for your selected option.

Returns

Approval is required. The 30-day window covers eligible products that have not been used or installed, with their original packaging and supplied contents retained.

For non-defective returns, you pay return shipping and may incur restocking charges of up to 20%. Processing fees of 3–4% are not refundable. The full policy explains exceptions and how to request a return.

Secure checkout · Protected payment
Authorized dealer · Victron warranty

No sales tax collected at checkout where applicable.

Need help choosing? Find the right setup for you. Talk it through with our team, or size your system with the Power Planner. Call 1-844-747-6767 Open Power Planner

Quantity

Your selection

Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W

In Stock
Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W
Quantity$1,088.00 each
1

Victron Energy

Victron MultiPlus-II 12/3000/120-50 2×120V Inverter Charger | 3,000VA, 2,400W

The 2×120V model accepts and passes through 120/240V split-phase input, but its battery inverter supplies 120V to both output legs. It does not produce 240V from the battery by itself.

Decision facts

  • Nominal Battery System: 12V
  • Continuous Output at 25°C: 3,000VA / 2,400W
  • Maximum Charge Current: 120A
  • Transfer Switch: 50A

Victron rates this model 3,000VA and 2,400W continuous at 25°C. Confirm the 2×120V wiring plan and loads.

Compare the Victron MultiPlus-II 12/3000/120-50 120V (UL 458) Inverter Charger – 3000W Pure Sine Wave Inverter & 120A Battery Charger for RV Marine & Off-Grid for a different rating or installation format. Check the exact model and manual before connecting equipment.

RV inverter sizing guide

Victron MultiPlus-II 12/3000/120-50 2x120V Inverter/Charger
Package Includes
1 Victron MultiPlus-II 12/3000/120-50 2x120V Inverter/Charger
Package Includes
1 Battery Temperature Sensor for Quattro/MultiPlus/GX (ASS000001000)
Victron MultiPlus-II 12/3000/120-50 2x120V (UL 458) Inverter Charger – 3000W Split-Phase Pure Sine Wave Inverter
Selected variant SKU PMP122305102
MODEL
Model / SKU PMP122305102
Product Type Inverter
ELECTRICAL
Nominal Battery System 12V
PowerControl and PowerAssist Yes
Transfer Switch 50A
Maximum AC Input Current 50A
DC Input Voltage Range 9.5–17V DC
Inverter Output 120V AC ±2%, 60Hz ±0.1%
Continuous Output at 25°C 3,000VA / 2,400W
Continuous Output at 40°C 2,200W
Continuous Output at 65°C 1,700W
Peak Power 5,500W
Maximum Efficiency 93%
Maximum Charge Current 120A
Charge Algorithm Adaptive four-stage with BatterySafe mode
PHYSICAL
Dimensions (H × W × D) 578 × 277 × 148 mm
Weight 22 kg
OPERATING LIMITS
Operating Temperature -40°C to +65°C; output derates above 40°C
Protection Rating IP22
PACKAGE
Included Components 1 × Victron MultiPlus-II 12/3000/120-50 2x120V Inverter/Charger, 1 × Battery Temperature Sensor for Quattro/MultiPlus/GX (ASS000001000)

Frequently Asked Questions

Clear answers to common questions about this product, setup, compatibility, and use.

How much continuous power does the MultiPlus-II 12/3000/120-50 2x120V provide? Victron rates it at 3,000VA and 2,400W continuous at 25°C, with 5,500W peak power. Output derates at higher temperature, so system design should use watts, temperature, surge demand, and power factor—not the model name alone. What battery bank does this MultiPlus-II require? This is the 12V model with a published DC input range of 9.5–17V DC. Battery chemistry, BMS, cables, fuse protection, and charger settings must all be compatible. How powerful is the built-in battery charger? The maximum listed charger output is 120A. The actual safe charge current may need to be reduced for the battery bank, BMS, wiring, temperature, and available AC input. Does the 2x120V model create 240V while inverting? No. With split-phase shore power present it passes both 120V legs through. In inverter mode it supplies 120V to both legs so 120V loads remain available, but 240V loads are not powered. What do PowerAssist and the transfer switch do? The 50A transfer switch passes qualified AC input to loads, while PowerAssist can supplement a limited AC source with inverter power. Configuration and branch protection must match the source, wiring, and connected loads. Does the MultiPlus-II include Bluetooth? Not as a built-in direct phone interface. Configuration and monitoring use supported Victron interfaces such as VE.Bus equipment, a GX device, or the appropriate Victron adapter.