Renogy REGO 3000W 12V Pure Sine Wave HF Split-Phase  Inverter Charger 1 / 11
Renogy

Renogy REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger Renogy REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger

SKU: RIV1230RCH-SPS-G2-US

Brand Renogy In Stock
$1,797.99 In Stock
No sales tax collected at checkout where applicable.
5% off Save 5% on eligible items Copy this code and apply it at checkout when eligible. Code: GET5
Extra 5% offUse GET5 at checkout

Applies to eligible items.

Estimated delivery Calculating current delivery window…
Secure checkoutProtected payment Free shippingView shipping policy Eligible returnsView return policy Authorized dealerRenogy warranty
Free shippingAuthorized dealer

Will this run what you need?

Check your setup with our team.

Shipping & returnsDelivery details, return eligibility & fees

Shipping
Free shipping. Check the availability and delivery information above for your selected option.

Returns

Approval is required. The 30-day window covers eligible products that have not been used or installed, with their original packaging and supplied contents retained.

For non-defective returns, you pay return shipping and may incur restocking charges of up to 20%. Processing fees of 3–4% are not refundable. The full policy explains exceptions and how to request a return.

Secure checkout · Protected payment
Authorized dealer · Renogy warranty

No sales tax collected at checkout where applicable.

Key features
  • Efficiency >92%
  • Optimal Efficiency >90%
Need help choosing? Find the right setup for you. Talk it through with our team, or size your system with the Power Planner. Call 1-844-747-6767 Open Power Planner

Quantity

Your selection

Renogy REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger

In Stock
Renogy REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger
Quantity$1,797.99 each
1

Split-Phase Inverter Charging

REGO 3000W 12V Pure Sine Wave High Frequency Inverter Charger

Combine high-frequency pure sine wave conversion with inverter charging support for compatible off-grid and mobile systems. The 240VAC output requires a split-phase 120/240VAC input source; verify the available source before planning 240V loads.

REGO 3000W high-frequency inverter charger split-phase design overview
REGO inverter charger system overview image

Low Noise Operation

High-frequency inverter design is presented for quieter compatible off-grid power use.

Low Noise Operation

Space-Saving Design

Compact form supports installation planning where equipment space is limited.

Space-Saving Design

High Environmental Adaptability

Check the specified operating-temperature and installation limits for the conditions where this inverter charger will be mounted.

High Environmental Adaptability

Enhanced Lithium Battery Activation and Heating Capability

Support compatible lithium battery charging workflows that include activation and heating features where applicable.

Enhanced Lithium Battery Activation and Heating Capability

Battery Temperature Sensor

Battery temperature sensing supports eligible charging management; follow Renogy battery compatibility guidance.

Battery Temperature Sensor

Swift Adaptation to Load Changes

The inverter charger is designed to respond quickly as supported AC load demand changes.

Swift Adaptation to Load Changes

Superior Safety

Safety protections support dependable operation in compatible installed power systems.

Superior Safety

Clearer Signals with Higher Frequency

High-frequency architecture supports clean pure sine wave AC output for suitable equipment.

System Design Overview

Use the system illustration below to review how the inverter charger fits with the other components in the installation.

System Design Overview

Compare a related option

Compare the high-frequency split-phase model with the LCD low-frequency model; their input arrangements and installation dimensions differ.

Renogy REGO 3000W 12V Pure Sine Wave Inverter Charger w/ LCD Display

REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger
Package Includes
1 REGO 3000W 12V Pure Sine Wave HF Split-Phase Inverter Charger
Quick Guide
Package Includes
1 Quick Guide
Self-Tapping Screw
Package Includes
8 Self-Tapping Screw
Dry Contact Relay Connector
Package Includes
1 Dry Contact Relay Connector
Wired Remote Control
Package Includes
1 Wired Remote Control
RJ12 Cable (5 m)
Package Includes
1 RJ12 Cable (5 m)
Battery Voltage Sensor
Package Includes
1 Battery Voltage Sensor
Battery Temperature Sensor
Package Includes
1 Battery Temperature Sensor
REGO 3000W 12V HF Pure Sine Wave Inverter Charger
Selected variant SKU RIV1230RCH-SPS-G2-US
Inverter
Continuous Power 3000W
Surge Power(100ms) 9000VA
Surge Power(5 seconds) 4500VA
Surge Power (10 seconds) 3600W
AC Output Voltage Range 120V± 3%
Output Frequency (Nominal) 50/60 Hz ± 0.1%
Output Waveform Pure Sine Wave
Efficiency >92%
THD <3%
DC Input Voltage DC12V
DC Input Voltage Range 9~17Vdc(Full load 11V to 15.8V DC)
No Load Current Draw Normal: <20W; Power Saving: <10W
Charger Specifications
Output Current 150A @25°C, 5A to 150A adjustable, 5A intervals, default 150A
Optimal Efficiency >90%
Nominal Input Voltage Split phase: 180-280 VAC; Single phase: 90-140 VAC
Input Frequency Range 50/60Hz,±5Hz
Input Wave Form Sine Wave (Utility or Generator)
Transferswitch Specifications
Transfer Time ~10ms
Transfer Rating 50A Maximum Bypass @120V AC
General Specification
Battery Types GEL, AGM, SLA, FLD, CAL, LI, USER
Noise <47dB
Operating Temperature Full load: -4°F to 113°F / -20°C to 45°C; Down load: 113°F to 140°F / 45°C to 60°C
Dimensions 19.37 x 13.11 x 5.31 in / 492 x 333 x 135 mm
Storage Temperature -40 ~ 70°C / -40 ~ 158°F
Weight 22.7lbs/10.3Kg
Humidity 0% ~ 95%
Wired Remote Control
Dimensions 2.8 x 4.3 x 1.3 in / 70 x 110 x 31.8 mm
Wire length Approx 16.4ft
Warranty
Material and workmanship warranty 5 Years
Accessories 1 Year
Certifications
EMC certification FCC Prat15 Class B
Safety UL 458 and CSA C22.2 No 107.1
Dimension tolerance ±0.2 in (0.5 mm)
Nominal Input Voltage Split phase 180V to 280V AC
Operating Temperature Range Full load -4°F to 113°F / -20°C to 45°C

Frequently Asked Questions

Clear answers to common questions about this product, setup, compatibility, and use.

Why choose the HF split-phase REGO over Renogy's earlier 3000W REGO inverter charger? Model RIV1230RCH-SPS uses a high-frequency design and supports North American 120/240V split-phase AC input. Renogy distinguishes it from the earlier standard-frequency RIV1230RCL-1SS model by its split-phase input support and higher shore-power load capacity. The two products should not be treated as interchangeable when planning AC input, bypass loads, mounting, or system communications. How much motor or compressor startup surge can the 3000W REGO handle? The inverter is rated for 3,000W continuous output and the manual publishes tiered surge limits: 9,000VA for 100ms, 4,500VA for 5 seconds, and 3,600W for 10 seconds. Whether it can start a specific air conditioner, pump, or refrigerator depends on that load's actual surge duration and power factor, not simply whether its running wattage is below 3,000W. Can shore power pass more than 3000W through this inverter charger? Yes, when the unit is supplied by 120V AC in bypass mode. Renogy publishes a 50A maximum bypass rating, equal to 6,000W at 120V, so bypass capacity can exceed the inverter's 3,000W battery-powered output. That larger bypass number does not increase the 3,000W inverter rating when shore power is absent. When does the REGO use shore power instead of the battery, and will it recharge the bank? The selected AC-output priority determines the behavior. In AC First mode, available grid or shore power supplies the loads and the charger can recharge the battery; in Battery First mode, the battery is favored while it remains within the configured limits. Renogy notes that the unit's own consumption comes from shore power in UPS mode but from the battery in battery-priority mode. What must the 12V battery bank support for this 3000W inverter charger? A 3,000W inverter on a 12V bank is a high-current installation, so the battery and BMS must support the inverter's continuous and surge demand, while the cables, busbars, fuse, and disconnect must be sized for the manual's DC requirements and actual run length. The charger can supply up to 150A and is adjustable from 5A to 150A; set that current within the battery manufacturer's permitted charge rate. Which REGO settings can be changed remotely, and is a system monitor included? A Renogy ONE Core and wired remote are included, and the inverter charger also supports built-in Bluetooth, the Renogy app, and RV-C integration. Supported remote adjustments include charging current, battery-protection parameters, and ECO mode. Renogy states that the app cannot power the inverter off, so remote monitoring does not replace the unit's physical controls or required disconnects. Does the REGO split-phase package include the high-current DC installation cables? The official package list includes the inverter charger, battery temperature sensor, voltage-detection line, wired remote, and Renogy ONE Core. It does not list the battery cables, DC fuse, disconnect, busbars, AC conductors, or site-specific protection hardware. Those components must be selected for the 12V high-current installation and the applicable electrical code before installation begins.