Renogy 12V 60A DC to DC On Board Battery Charger 1 / 6
Renogy

Renogy 12V 60A DC to DC On Board Battery Charger Renogy 12V 60A DC to DC On Board Battery Charger

SKU: RNG-DCC1212-60-G1-US

Brand Renogy In Stock
$224.99 In Stock
No sales tax collected at checkout where applicable.
5% off Save 5% on eligible items Copy this code and apply it at checkout when eligible. Code: GET5
Extra 5% offUse GET5 at checkout

Applies to eligible items.

Estimated delivery Calculating current delivery window…
Secure checkoutProtected payment Free shippingView shipping policy Eligible returnsView return policy Authorized dealerRenogy warranty
Free shippingAuthorized dealer

Will this run what you need?

Check your setup with our team.

Shipping & returnsDelivery details, return eligibility & fees

Shipping
Free shipping. Check the availability and delivery information above for your selected option.

Returns

Approval is required. The 30-day window covers eligible products that have not been used or installed, with their original packaging and supplied contents retained.

For non-defective returns, you pay return shipping and may incur restocking charges of up to 20%. Processing fees of 3–4% are not refundable. The full policy explains exceptions and how to request a return.

Secure checkout · Protected payment
Authorized dealer · Renogy warranty

No sales tax collected at checkout where applicable.

Key features
  • Charging output Up to 60A / 750W
  • Reduced-current setting 30A via LC terminal
  • Charging source 12V vehicle; no solar input
Need help choosing? Find the right setup for you. Talk it through with our team, or size your system with the Power Planner. Call 1-844-747-6767 Open Power Planner

Quantity

Your selection

Renogy 12V 60A DC to DC On Board Battery Charger

In Stock
Renogy 12V 60A DC to DC On Board Battery Charger
Quantity$224.99 each
1

60A alternator charging for a 12V house battery

The Renogy RNG-DCC1212-60 is an onboard battery-to-battery charger for RVs, vans and other compatible 12V vehicle systems. It converts power from the starter-battery side into a controlled charge for a separate house battery, with up to 60A charging output and a 750W maximum. This is the original DIP-switch model, without Bluetooth or a direct solar-panel input.

Renogy 12V 60A DC to DC On Board Battery Charger
Original 60A onboard charger; D+ ignition wiring required.

Check alternator capacity before choosing 60A

The 60A label describes charging output, not the total current drawn from the vehicle. Renogy’s manual warns that input current can be up to 50% higher than output current. Account for lights, fans, vehicle electronics and the alternator’s available output at the engine speeds you actually use. The manual’s 60A-model fuse recommendations are approximately 90A on the starter side and 75A on the house side; cable length, routing and terminal fit determine the final installation.

D+ is required; LC provides a 30A setting

This charger does not operate until its D+ terminal receives the required ignition signal. The ignition wire is separate and must follow the vehicle’s wiring documentation. Connecting the LC current-limit terminal to the specified 12V signal reduces the rated charging current from 60A to 30A. That provides a lower-current option for a suitably sized battery or vehicle system; it does not replace checking the alternator’s limits.

Choose the correct lead-acid or lithium profile

DIP switches set the battery type and charge voltage. The manufacturer supports AGM, flooded, gel and compatible lithium batteries, with a published 13.2–14.7V lead-acid charging range and 12.6–14.6V lithium range. Set the switches for the exact battery’s requirements and BMS current limit. The optional RTSDCC temperature sensor is for lead-acid compensation and must not be used with lithium batteries.

Plan charging time and mounting space

For scale, replacing 50Ah at a steady 60A would take about 50 minutes before tapering and losses; at the LC-limited 30A setting, the same calculation is 100 minutes. These are calculations, not guaranteed charging times. Battery acceptance, vehicle loads, temperature and cable losses change actual results. The charger measures 311 × 175 × 68 mm and weighs 2.4 kg. Install in a dry, ventilated location with the manual’s minimum 5 cm clearance.

What’s in the box

Renogy’s confirmed retail package lists one 60A DC-DC charger. Main power cables, battery fuses, the D+ ignition wire and the optional temperature sensor must be planned separately. The downloadable manual below provides the model-specific wiring, fuse and DIP-switch tables.

Compare charging options

For a smaller current requirement, compare the Renogy 20A onboard charger. For built-in Bluetooth and conditional starter-battery maintenance, compare the REGO 60A charger. If you need direct solar input, choose an appropriate DC-DC charger with MPPT. Our RV DC-to-DC charging guide and Renogy controller and charger collection explain the different jobs these devices perform.

Manual and warranty

The Documentation tab provides the 20A/40A/60A family manual and Renogy US Limited Warranty A7. One-year material and workmanship coverage applies under that policy. Check the 60A instructions when using shared-model tables.

Renogy DCC1212 60A onboard DC-DC charger
Package Includes
1 × Renogy DCC1212 60A onboard DC-DC charger
Selected Product SKU RNG-DCC1212-60-G1-US
Chargers in Selected Pack 1
Manufacturer Model RNG-DCC1212-60-G1-US
System Voltage 12V to 12V
Input Voltage Range 8V to 16V DC
Rated Charge Current 60A maximum
Maximum Output Power 750W
LC Current-Limit Setting 30A when LC terminal receives the specified 12V signal
Lead-Acid Charge Voltage Range 13.2V to 14.7V
Lithium Charge Voltage Range 12.6V to 14.6V
Float Voltage 13.2V to 13.8V; lead-acid profile dependent
Boost Voltage 14.1V to 14.7V; lead-acid profile dependent
Equalization Voltage Not applicable
Battery Types AGM, flooded, gel and compatible lithium; set DIP switches to battery requirements
D+ Ignition Signal Required for operation; ignition wire sold separately
Direct Solar Input No; separate solar controller required
Bluetooth Not built in
Maximum Input Current Planning Manual warns input draw may be up to 50% above rated output current
Input Fuse Guidance 90A or close, per manual 60A column; installer must size for actual wiring
Output Fuse Guidance 75A or close, per manual 60A column; installer must size for actual wiring
Efficiency 90% per manual
Residual Output Ripple Less than 50mV at rated current
Idle Current 0.4A per manual; retail specifies less than 0.4A
Operating Temperature -20°C to 50°C / -4°F to 122°F
Humidity Up to 95%, non-condensing
Dimensions 311 x 175 x 68 mm / 12.2 x 6.9 x 2.7 in
Weight 2.4 kg / 5.3 lb
Temperature Sensor Optional RTSDCC; lead-acid only
Temperature Compensation -3mV/°C/2V; not for lithium
Ventilation Clearance At least 5 cm around charger; dry, ventilated mounting
Input Protection High/low voltage, reverse polarity, high temperature and short circuit
Low-Voltage Cutoff / Restart 8V / 10V per manufacturer retail specifications
High-Voltage Shutdown / Restart 16V / 15.5V per manufacturer retail specifications
Certification CE per manual; retail also lists RoHS
Warranty 1-year material and workmanship coverage under Renogy US Limited Warranty A7
Selected variant SKU RNG-DCC1212-60-G1-US
Product reference specifications

Specifications for the selected option are shown above. These product reference details describe the listing and its available configurations.

Manufacturer ModelRNG-DCC1212-60-G1-US
System Voltage12V to 12V
Input Voltage Range8V to 16V DC
Rated Charge Current60A maximum
Maximum Output Power750W
LC Current-Limit Setting30A when LC terminal receives the specified 12V signal
Lead-Acid Charge Voltage Range13.2V to 14.7V
Lithium Charge Voltage Range12.6V to 14.6V
Float Voltage13.2V to 13.8V; lead-acid profile dependent
Boost Voltage14.1V to 14.7V; lead-acid profile dependent
Equalization VoltageNot applicable
Battery TypesAGM, flooded, gel and compatible lithium; set DIP switches to battery requirements
D+ Ignition SignalRequired for operation; ignition wire sold separately
Direct Solar InputNo; separate solar controller required
BluetoothNot built in
Maximum Input Current PlanningManual warns input draw may be up to 50% above rated output current
Input Fuse Guidance90A or close, per manual 60A column; installer must size for actual wiring
Output Fuse Guidance75A or close, per manual 60A column; installer must size for actual wiring
Efficiency90% per manual
Residual Output RippleLess than 50mV at rated current
Idle Current0.4A per manual; retail specifies less than 0.4A
Operating Temperature-20°C to 50°C / -4°F to 122°F
HumidityUp to 95%, non-condensing
Dimensions311 x 175 x 68 mm / 12.2 x 6.9 x 2.7 in
Weight2.4 kg / 5.3 lb
Temperature SensorOptional RTSDCC; lead-acid only
Temperature Compensation-3mV/°C/2V; not for lithium
Ventilation ClearanceAt least 5 cm around charger; dry, ventilated mounting
Input ProtectionHigh/low voltage, reverse polarity, high temperature and short circuit
Low-Voltage Cutoff / Restart8V / 10V per manufacturer retail specifications
High-Voltage Shutdown / Restart16V / 15.5V per manufacturer retail specifications
CertificationCE per manual; retail also lists RoHS
Warranty1-year material and workmanship coverage under Renogy US Limited Warranty A7

Frequently Asked Questions

Clear answers to common questions about this product, setup, compatibility, and use.

Does the 60A charger need a D+ ignition wire? Yes. The RNG-DCC1212-60 does not operate until the D+ terminal receives the required ignition signal. The wire is not included in the confirmed retail package. Follow the vehicle electrical diagram and Renogy manual for the signal connection. Can I reduce it to 30A? Yes. Renogy documents a 50% current-limit function. Applying the specified 12V signal to the LC terminal changes this 60A model to 30A. Choose the setting around the battery charge-current limit and the vehicle’s spare alternator capacity. Will the vehicle supply only 60A to it? Not necessarily. 60A is the rated output. Renogy warns that input current may be up to 50% higher because of voltage conversion and losses. Include the vehicle’s other loads when evaluating alternator capacity and wiring. Does it charge directly from solar panels? No. This is an alternator-to-house-battery charger without an MPPT input. Use a separate compatible solar controller, or choose a DC-DC model that explicitly includes solar MPPT. How long does charging take? As an ideal calculation, replacing 50Ah takes 50 minutes at 60A or 100 minutes at 30A. Actual time is longer when charging tapers or output is reduced by battery acceptance, vehicle loads, voltage drop or temperature. Can I use the temperature sensor with lithium? No. The optional RTSDCC sensor provides lead-acid temperature compensation. Renogy says not to use it with lithium batteries. Follow the lithium battery manufacturer’s charging temperature and BMS limits. What else is needed for installation? The confirmed retail contents list one charger. Select appropriate input/output cables, fuses, ignition wiring and mounting hardware for the vehicle. The manual’s 60A column recommends approximately 90A input and 75A output fusing; those recommendations do not replace installer cable and protection sizing. What is different about REGO 60A? The original model uses DIP switches, requires a D+ signal and has an LC 30A mode. REGO uses a different 800W design with Anderson connections, built-in Bluetooth and conditional bidirectional charging. Their wiring and manuals are not interchangeable.