Renogy 12V 60A DC to DC On Board Battery Charger Renogy 12V 60A DC to DC On Board Battery Charger
SKU: RNG-DCC1212-60-G1-US
- Charging output Up to 60A / 750W
- Reduced-current setting 30A via LC terminal
- Charging source 12V vehicle; no solar input
60A alternator charging for a 12V house battery
The Renogy RNG-DCC1212-60 is an onboard battery-to-battery charger for RVs, vans and other compatible 12V vehicle systems. It converts power from the starter-battery side into a controlled charge for a separate house battery, with up to 60A charging output and a 750W maximum. This is the original DIP-switch model, without Bluetooth or a direct solar-panel input.

Check alternator capacity before choosing 60A
The 60A label describes charging output, not the total current drawn from the vehicle. Renogy’s manual warns that input current can be up to 50% higher than output current. Account for lights, fans, vehicle electronics and the alternator’s available output at the engine speeds you actually use. The manual’s 60A-model fuse recommendations are approximately 90A on the starter side and 75A on the house side; cable length, routing and terminal fit determine the final installation.
D+ is required; LC provides a 30A setting
This charger does not operate until its D+ terminal receives the required ignition signal. The ignition wire is separate and must follow the vehicle’s wiring documentation. Connecting the LC current-limit terminal to the specified 12V signal reduces the rated charging current from 60A to 30A. That provides a lower-current option for a suitably sized battery or vehicle system; it does not replace checking the alternator’s limits.
Choose the correct lead-acid or lithium profile
DIP switches set the battery type and charge voltage. The manufacturer supports AGM, flooded, gel and compatible lithium batteries, with a published 13.2–14.7V lead-acid charging range and 12.6–14.6V lithium range. Set the switches for the exact battery’s requirements and BMS current limit. The optional RTSDCC temperature sensor is for lead-acid compensation and must not be used with lithium batteries.
Plan charging time and mounting space
For scale, replacing 50Ah at a steady 60A would take about 50 minutes before tapering and losses; at the LC-limited 30A setting, the same calculation is 100 minutes. These are calculations, not guaranteed charging times. Battery acceptance, vehicle loads, temperature and cable losses change actual results. The charger measures 311 × 175 × 68 mm and weighs 2.4 kg. Install in a dry, ventilated location with the manual’s minimum 5 cm clearance.
What’s in the box
Renogy’s confirmed retail package lists one 60A DC-DC charger. Main power cables, battery fuses, the D+ ignition wire and the optional temperature sensor must be planned separately. The downloadable manual below provides the model-specific wiring, fuse and DIP-switch tables.
Compare charging options
For a smaller current requirement, compare the Renogy 20A onboard charger. For built-in Bluetooth and conditional starter-battery maintenance, compare the REGO 60A charger. If you need direct solar input, choose an appropriate DC-DC charger with MPPT. Our RV DC-to-DC charging guide and Renogy controller and charger collection explain the different jobs these devices perform.
Manual and warranty
The Documentation tab provides the 20A/40A/60A family manual and Renogy US Limited Warranty A7. One-year material and workmanship coverage applies under that policy. Check the 60A instructions when using shared-model tables.
| Selected Product SKU | RNG-DCC1212-60-G1-US |
|---|---|
| Chargers in Selected Pack | 1 |
| Manufacturer Model | RNG-DCC1212-60-G1-US |
| System Voltage | 12V to 12V |
| Input Voltage Range | 8V to 16V DC |
| Rated Charge Current | 60A maximum |
| Maximum Output Power | 750W |
| LC Current-Limit Setting | 30A when LC terminal receives the specified 12V signal |
| Lead-Acid Charge Voltage Range | 13.2V to 14.7V |
| Lithium Charge Voltage Range | 12.6V to 14.6V |
| Float Voltage | 13.2V to 13.8V; lead-acid profile dependent |
| Boost Voltage | 14.1V to 14.7V; lead-acid profile dependent |
| Equalization Voltage | Not applicable |
| Battery Types | AGM, flooded, gel and compatible lithium; set DIP switches to battery requirements |
| D+ Ignition Signal | Required for operation; ignition wire sold separately |
| Direct Solar Input | No; separate solar controller required |
| Bluetooth | Not built in |
| Maximum Input Current Planning | Manual warns input draw may be up to 50% above rated output current |
| Input Fuse Guidance | 90A or close, per manual 60A column; installer must size for actual wiring |
| Output Fuse Guidance | 75A or close, per manual 60A column; installer must size for actual wiring |
| Efficiency | 90% per manual |
| Residual Output Ripple | Less than 50mV at rated current |
| Idle Current | 0.4A per manual; retail specifies less than 0.4A |
| Operating Temperature | -20°C to 50°C / -4°F to 122°F |
| Humidity | Up to 95%, non-condensing |
| Dimensions | 311 x 175 x 68 mm / 12.2 x 6.9 x 2.7 in |
| Weight | 2.4 kg / 5.3 lb |
| Temperature Sensor | Optional RTSDCC; lead-acid only |
| Temperature Compensation | -3mV/°C/2V; not for lithium |
| Ventilation Clearance | At least 5 cm around charger; dry, ventilated mounting |
| Input Protection | High/low voltage, reverse polarity, high temperature and short circuit |
| Low-Voltage Cutoff / Restart | 8V / 10V per manufacturer retail specifications |
| High-Voltage Shutdown / Restart | 16V / 15.5V per manufacturer retail specifications |
| Certification | CE per manual; retail also lists RoHS |
| Warranty | 1-year material and workmanship coverage under Renogy US Limited Warranty A7 |
| Selected variant SKU | RNG-DCC1212-60-G1-US |
Product reference specifications
Specifications for the selected option are shown above. These product reference details describe the listing and its available configurations.
| Manufacturer Model | RNG-DCC1212-60-G1-US |
|---|---|
| System Voltage | 12V to 12V |
| Input Voltage Range | 8V to 16V DC |
| Rated Charge Current | 60A maximum |
| Maximum Output Power | 750W |
| LC Current-Limit Setting | 30A when LC terminal receives the specified 12V signal |
| Lead-Acid Charge Voltage Range | 13.2V to 14.7V |
| Lithium Charge Voltage Range | 12.6V to 14.6V |
| Float Voltage | 13.2V to 13.8V; lead-acid profile dependent |
| Boost Voltage | 14.1V to 14.7V; lead-acid profile dependent |
| Equalization Voltage | Not applicable |
| Battery Types | AGM, flooded, gel and compatible lithium; set DIP switches to battery requirements |
| D+ Ignition Signal | Required for operation; ignition wire sold separately |
| Direct Solar Input | No; separate solar controller required |
| Bluetooth | Not built in |
| Maximum Input Current Planning | Manual warns input draw may be up to 50% above rated output current |
| Input Fuse Guidance | 90A or close, per manual 60A column; installer must size for actual wiring |
| Output Fuse Guidance | 75A or close, per manual 60A column; installer must size for actual wiring |
| Efficiency | 90% per manual |
| Residual Output Ripple | Less than 50mV at rated current |
| Idle Current | 0.4A per manual; retail specifies less than 0.4A |
| Operating Temperature | -20°C to 50°C / -4°F to 122°F |
| Humidity | Up to 95%, non-condensing |
| Dimensions | 311 x 175 x 68 mm / 12.2 x 6.9 x 2.7 in |
| Weight | 2.4 kg / 5.3 lb |
| Temperature Sensor | Optional RTSDCC; lead-acid only |
| Temperature Compensation | -3mV/°C/2V; not for lithium |
| Ventilation Clearance | At least 5 cm around charger; dry, ventilated mounting |
| Input Protection | High/low voltage, reverse polarity, high temperature and short circuit |
| Low-Voltage Cutoff / Restart | 8V / 10V per manufacturer retail specifications |
| High-Voltage Shutdown / Restart | 16V / 15.5V per manufacturer retail specifications |
| Certification | CE per manual; retail also lists RoHS |
| Warranty | 1-year material and workmanship coverage under Renogy US Limited Warranty A7 |
Frequently Asked Questions
Clear answers to common questions about this product, setup, compatibility, and use.