Renogy Rover 100A MPPT Solar Charge Controller Renogy Rover 100A MPPT Solar Charge Controller
SKU: RNG-CTRL-RVR100-G2-US
- Battery charging 100A
- Solar at 12V 1300W
- Bluetooth module Separate
Choose the Rover 100A for the right battery system
Choose by battery voltage and array size. Renogy specifies a 150V PV limit at 25°C and 140V at −25°C; cold-weather design is essential.
Battery system: 12V, 24V, 36V or 48V. Renogy’s array guidance is 1300W at 12V, 2600W at 24V, 3900W at 36V or 5200W at 48V. Check panel voltage, current and cold-weather open-circuit voltage before selecting a wiring arrangement.
Use our solar charge-controller sizing guide to plan the system. For a smaller 12V/24V installation, compare Rover Li 40A.
Large-Capacity Rover MPPT Control
Rover 100 Amp MPPT Solar Charge Controller
Build a high-capacity compatible solar charging system with Renogy's largest Rover controller, designed for multiple system voltages, monitoring support and parallel-controller expansion.
Large-System Charging
Renogy describes support for 1300W at 12V, 2600W at 24V, 3900W at 36V and 5200W at 48V.
Parallel Expansion
Two compatible 100A controllers can operate in parallel for a stated total of 200A.
High MPPT Efficiency
Renogy states up to 99% tracking efficiency and 98% peak conversion efficiency.
Compatible Smart Monitoring
Use compatible Bluetooth or Renogy monitoring hardware to view eligible charge-controller information through supported Renogy apps.
Rover Bluetooth Module Guide
Use the Rover Bluetooth module guide below when setting up a compatible remote monitoring accessory.
Key Description Features
- Automatic system-voltage detection for supported non-lithium batteries.
- Compatible charging support for common lead-acid and lithium battery types.
- Built-in electrical protections for compatible off-grid charging systems.
- LCD and LED indicators for monitoring operating information.
- RS232 and RS485 communication support for compatible modules.
Size the charging system
Use our solar charge controller sizing guide to compare controller current and voltage limits. The MPPT versus PWM guide explains how MPPT and PWM designs differ.
Compare this Renogy model
100A rated charging, 150VDC (25°C), 140VDC(-25°C) PV input, 1300W/12V; 2600W/24V; 3900W/36V; 5200W/48V PV power. Compare voltage, current and battery profiles.
Compare Rover Li 40A by electrical ratings, dimensions, features and selected pack quantity before ordering.
Rover 100A: solar sizing, package and installation
Choose this 100A MPPT controller for a 12V, 24V, 36V or 48V battery bank. This is the controller-only package; Bluetooth is separate. The amp rating is battery charging output, not panel current or AC output.
Match the solar array to the battery bank
The 100A model allows 1,300W/12V, 2,600W/24V, 3,900W/36V or 5,200W/48V. These are battery-voltage-specific allowances, not a 5,200W allowance on every bank. The included paralleling cable is for compatible Rover 100A controllers; each controller retains its own electrical input and charging limits.
PV open-circuit limits are 150V at 25°C and 140V at −25°C. The A6 manual separately lists an MPPT working range from battery voltage +2V to 75V. A high open-circuit ceiling does not mean the controller tracks maximum power throughout that entire range.
Know the connections before installation
This model has RS232 and RS485 communications. Use BT-1 with RS232 or BT-2 with RS485; the controller-only package does not include either module.
The Rover 100A is a battery charger, with PV and battery power terminals. Connect an inverter or large DC loads through the properly protected battery system, not through a controller communications port.
Mount the IP32 controller vertically in a dry, ventilated location with the manual’s clearances. It is not a weatherproof rooftop enclosure. Connect and configure the battery before connecting the solar array. Lithium bank voltage and charge settings must match the battery manual; non-lithium auto-detection is not lithium setup.
What’s included with this package
- 1 × Rover 100A MPPT Solar Charge Controller
- 1 × Renogy Rover 100A remote temperature sensor
- 1 × Renogy Rover 100A controller paralleling cable
Solar panels, batteries, inverter, system cabling and external circuit protection are separate. The linked controller manual covers setup; a Bluetooth module does not replace a battery heater or battery protection system.
Compare the next size or package
Compare Rover 60A, browse Renogy charge controllers, or use the solar charge controller sizing guide to check your array and bank together.
| Rover 100A — specifications | |
| Selected variant SKU | RNG-CTRL-RVR100-G2-US |
|---|---|
| Nominal Voltage | 12V/24V/36V/48V Auto Recognition (for non-lithium batteries) |
| Rated Charge Current | 100A |
| Max. PV Input Power | 1300W/12V; 2600W/24V; 3900W/36V; 5200W/48V |
| Max. PV Input Voltage | 150VDC (25°C), 140VDC(-25°C) |
| Self-Consumption | 2.7W - 2.9W |
| Operating Temperature | -35°C to +45°C |
| Temperature Compensation | -3mV/°C/2V (default) |
| Dimensions | 12.00 x 17.44 x 4.35 in |
| Weight | 22 lb / 9.98 kg (A6 manual) |
| Enclosure | IP32 |
| Terminals | 25mm2, 4AWG |
| Certification | FCC Part 15 Class B; CE; RoHS (A6 manual) |
| Warranty | 3-year material and workmanship warranty |
| Bluetooth Package | Module not included |
| Battery Voltage Selection | 12V / 24V / 36V / 48V; lithium voltage set manually |
| Specification Reference | Rover 100A A6 manual (March 2026) |
| Battery Input Voltage Range | 9V to 60V DC |
| MPPT Operating Voltage Range | Battery voltage +2V to 75V (A6 manual) |
| Communication | RS232 / BT-1 or RS485 / BT-2; modules separate |
| Storage Temperature | -35°C to 75°C / -31°F to 167°F |
| Humidity | ≤95%, non-condensing |
| Grounding | Common negative |
| Included Parallel Accessory | Rover 100A controller paralleling cable; per-controller electrical limits still apply |
Frequently Asked Questions