Renogy Rover Li 30A MPPT Solar Charge Controller Renogy Rover Li 30A MPPT Solar Charge Controller
SKU: RNG-CTRL-RVR30-G3-US
- Battery charging 30A
- Solar at 12V 400W
- Bluetooth module Separate
Choose the Rover Li 30A for your battery bank
This is the controller-only package; the Bluetooth module is a separate purchase. The 30A version supports up to 400W of solar on 12V or 800W on 24V. Choose by battery voltage and array size before choosing the monitoring package.
| Rover Li 20A | 260W / 520W |
| Rover Li 30A | 400W / 800W |
| Rover Li 40A | 520W / 1040W |
Allow for the increase in panel open-circuit voltage in cold weather; do not design an array at the 100V ceiling.
Compare the package with Bluetooth or use our charge-controller sizing guide.
Rover Li MPPT Charging
Rover Li 30 Amp MPPT Solar Charge Controller
Support efficient battery charging for compatible off-grid systems with a Rover Li MPPT controller designed for protection, heat dissipation and lithium battery activation.
Upgrade Your Charging Controller
The Rover Li 30A is built to manage solar charging efficiently for compatible off-grid energy systems.

Comprehensive Internal and External Protection
Built-in system safeguards and protected construction support reliable controller operation.

Rapid Heat Dissipation
The heat-dissipation structure helps control temperature during charger operation.

Powering Your Adventures Faster
MPPT charging is designed to maximize available solar input for compatible battery charging.

Revive Lithium Batteries from Protection Mode
Lithium-battery activation support helps wake a compatible protected lithium battery using a small charging current.

ROVER Bluetooth Module Guide
Use the supported Bluetooth module for compatible remote-monitoring setup.

Size the Rover Li 30A from the battery and solar array
The 30A model supports up to 400W at 12V or 800W at 24V. Its PV input absolute maximum is 100VDC; Renogy recommends no more than 95V in low temperatures. Confirm cold-corrected array Voc, battery chemistry, charge profile, and wire/terminal limits. Auto-detection of system voltage applies to non-lithium battery types; set lithium voltage explicitly as the manual instructs.
Compare the Rover Li 20A and Rover Li 40A when sizing a different charge current. The base 30A listing does not include the separate Bluetooth module.
Size the charging system
Use our solar charge controller sizing guide to compare controller current and voltage limits. The MPPT versus PWM guide explains how MPPT and PWM designs differ.
Rover Li 30A: solar sizing, package and installation
Choose this 30A MPPT controller for a 12V or 24V battery bank. This is the controller-only package; Bluetooth is separate. The amp rating is battery charging output, not panel current or AC output.
Match the solar array to the battery bank
A 400W array is the rated allowance at 12V; a 24V bank raises it to 800W. A 400W array uses the full published 12V allowance. If you plan more panel wattage later, compare the 40A model before sizing the battery-side wiring.
The current B3 manual lists 100V maximum PV open-circuit voltage. Check the array’s cold-corrected Voc; a panel’s nominal 12V label is not its open-circuit voltage.
Know the connections before installation
Renogy’s current Rover Li manual and retail options use RS485 with a BT-2 module. Older Rover units can have RS232/BT-1 hardware, so match the port on the supplied unit before replacing a module.
The managed DC load output is limited to 20A, separately from the battery charging rating. Large loads and inverters need their own protected battery connection.
Mount the IP32 controller vertically in a dry, ventilated location with the manual’s clearances. It is not a weatherproof rooftop enclosure. Connect and configure the battery before connecting the solar array. Lithium bank voltage and charge settings must match the battery manual; non-lithium auto-detection is not lithium setup.
What’s included with this package
- 1 × Rover Li 30A MPPT Solar Charge Controller
- 1 × Renogy Rover Li quick guide
- 1 × Renogy RTSCC battery temperature sensor
- 4 × Rover Li mounting brackets
- 4 × Rover Li mounting bracket screws
Solar panels, batteries, inverter, system cabling and external circuit protection are separate. The linked controller manual covers setup; a Bluetooth module does not replace a battery heater or battery protection system.
Compare the next size or package
Compare Rover Li 40A with Bluetooth, browse Renogy charge controllers, or use the solar charge controller sizing guide to check your array and bank together.
| Rover Li 30A — specifications | |
| Selected variant SKU | RNG-CTRL-RVR30-G3-US |
|---|---|
| Nominal System Voltage | 12/24V (Auto-Detect for Non-Lithium types) |
| Rated Charge Current | 30A |
| Max. PV Input Voltage | 100V B3 manual; retail recommends 95V in cold conditions |
| Max. PV Input Power | 12V/400W, 24V/800W |
| Power Consumption | <100mA/12V; <58mA/24V |
| Ground Type | Negative |
| Electrical Protection | Overcharging, over-discharging, overload, and short circuit. Capable of charging over-discharged lithium batteries |
| Protection Level | IP32 |
| Operating Temperature Range | -35°C to 45°C (-31°F to 113°F) |
| Storage Temperature Range | -35°C to 75°C (-31°F to 167°F) |
| Operating / Storage Humidity | 0% to 95% RH (B3 manual); prevent condensation |
| Temperature Compensation | Non-lithium: -3mV/°C/2V; lithium: no compensation |
| Dimensions | 238 x 172 x 77 mm; 9.38 x 6.78 x 3.05 in |
| Weight | 4.4 lbs / 2.0 kg |
| Max. Terminals Size | 8 AWG 10mm² |
| CE | YES |
| FCC Class B Part 15 Compliant | YES |
| Material and workmanship warranty | 3 Year |
| Bluetooth Package | Module not included |
| Battery Voltage Selection | 12V / 24V; lithium voltage set manually |
| Specification Reference | Current Rover Li B3 manual (January 2026); inspect supplied hardware port |
| Rated Load Current | 20A DC |
| Battery Input Voltage Range | 10V to 32V DC |
| Communication | RS485 / BT-2 in current B3 manual; older RS232 units use BT-1 |
| MPPT Operating Voltage Range | 17V to 100V DC (B3 manual) |
| Charging Profiles | AGM, Gel, Flooded, Lithium, User-defined |
| Charging Algorithm | Lead acid: Bulk/Boost/Float with Equalization; lithium: Bulk/Boost |
Frequently Asked Questions