Rich Solar ALPHA 2 PRO | 12V 200Ah LiFePO4 Battery | Premium 12V Lithium Battery for RVs, Cabins, Tiny Homes | 7,000 Lifetime Cycles | 10 Year Warranty | UL1973 Certified
Frequently Bought Together
Rich Solar ALPHA 2 PRO 12V 200Ah LiFePO4 Battery
The Rich Solar ALPHA 2 PRO is a premium 12V 200Ah lithium iron phosphate battery built for RVs, vans, cabins, tiny homes, marine systems, and off-grid solar storage. With 2560Wh of energy capacity, 7,000+ lifetime cycles, internal heat technology, a Safe BMS System, industrial-grade battery cells, UL1973 certification, and a 10-year warranty, it gives serious 12V power systems a long-life lithium storage foundation.
Product Overview
The ALPHA 2 PRO is designed for customers who want a higher-end 12V lithium battery with stronger cycle life, premium protection, and better long-term durability. It is a strong fit for RV solar systems, camper vans, travel trailers, cabins, tiny homes, boats, and off-grid solar storage builds where dependable battery capacity matters.
Compared with traditional lead-acid storage, LiFePO4 chemistry offers longer service life, more usable energy, lower maintenance, and more consistent performance over time. The ALPHA 2 PRO adds internal heating, high-quality battery cells, and a Safe BMS System to support more demanding mobile and off-grid use.
Built for Premium 12V Solar and Off-Grid Power
The ALPHA 2 PRO gives 12V systems a powerful lithium battery upgrade with the capacity, cycle life, and protection needed for real RV, marine, cabin, and off-grid use. It is ideal for customers who want more than a basic battery and are building a system they expect to rely on for years.
Key Features That Matter
The ALPHA 2 PRO focuses on the features customers actually care about when choosing a premium 12V lithium battery: cold-weather support, long cycle life, safer battery management, and higher-grade cell construction.
Internal heating helps improve cold-weather usability for RVs, trailers, cabins, marine compartments, and seasonal off-grid systems. It is especially useful when battery charging conditions can drop below normal lithium charging temperatures.
Designed for consistent and durable performance, the ALPHA 2 PRO gives solar, RV, marine, and off-grid users a longer-lasting battery option than traditional lead-acid storage and many basic lithium batteries.
The Safe BMS System helps the battery respond accurately and quickly to abnormal conditions, including overcharge, over-discharge, overcurrent, short-circuit, low temperature, and high temperature situations.
Premium cell construction helps support long-term durability, stable output, and dependable performance for customers who expect their battery bank to handle regular solar, RV, marine, or off-grid use.
Best Uses
- RV solar battery banks
- Camper vans and travel trailers
- Cabins, tiny homes, and shed power systems
- Marine and boat electrical systems
- Off-grid solar energy storage
- Backup power for essential 12V loads
- Premium lead-acid battery replacement projects
- Long-term 12V solar storage builds
Key Benefits
- 12V 200Ah LiFePO4 lithium battery
- 2560Wh energy storage capacity
- 7,000+ lifetime cycles
- Internal heat technology for colder environments
- Safe BMS System protection
- Industrial-grade battery cells
- UL1973 certified
- Premium 10-year warranty
- Designed for RVs, cabins, tiny homes, marine, and off-grid power
| Specifications | |
| Model SKU | RS-B122SP |
|---|---|
| Battery Type | LFP Battery |
| Nominal Voltage | 12.8V |
| Nominal Capacity | 200Ah |
| Minimum Capacity | 200Ah |
| Nominal Energy | 2,560Wh |
| Charging Voltage | 14.4V |
| Discharging Cutoff Voltage | 11.2V |
| Standard Charging Current | 100A |
| Maximum Charging Current | 200A |
| Standard Discharge Current | 100A |
| Continuous Discharge Current | 200A |
| Maximum Discharge Current | 200A |
| Shell Material | Plastic Shell |
| Weight | About 52.9 lbs / 24.0kg |
| Initial AC (1000Hz) Internal Resistance | ≤50mΩ (New Battery within 3 Months) |
| Monthly Self-Discharge Rate | ≤5% |
| Overall Dimensions | 20.9 x 8.1 x 8.5 in |
| Cycle Life (25°C ± 2°C) | ≥7,000 |
| Communication Mode | Bluetooth |
| Discharge Temperature | -4°F to 140°F / -20°C to 60°C (Cell Surface Should Not Exceed 60°C) |
| Storage Temperature | -22°F to 131°F / -30°C to 55°C, 90% RH Max (Less than 1 Month); 14°F to 113°F / -10°C to 45°C, 90% RH Max (More than 3 Months) |
| Recommended Storage Temperature | 14°F to 95°F / -10°C to 35°C, 85% RH Max |
| BMS Operation | |
| Typical Charging Current | 100A |
| Maximum Charging Current | 200A |
| Typical Discharge Current | 100A |
| Maximum Discharge Current | 200A |
| Maximum Charge Voltage (CC/CV) | 14.4V |
| Over Charge Protection Voltage (Cell) | 3.65V ± 0.05V |
| Over Charge Protection Delay Time | 2,000ms ± 1,000ms |
| Over Charge Protection Recovery Voltage (Cell) | 3.55V ± 0.05V |
| Over Discharge Protection Voltage (Cell) | 2.50V ± 0.10V |
| Over Discharge Protection Delay Time | 2,000ms ± 1,000ms |
| Over Discharge Protection Recovery Voltage (Cell) | 3.00V ± 0.10V |
| Over Discharge Protection Release Conditions | Charge Recovery or Voltage Self-Recovery within 60s ± 20s |
| Primary Charge Overcurrent Protection Value | 220A ± 10A |
| First Stage Charge Overcurrent Delay | 10s ± 3s |
| Overcurrent Charge Release Conditions | Automatic Recovery After a Delay of 32s ± 7s |
| Primary Discharge Overcurrent Protection Value | 220A ± 10A |
| Primary Discharge Overcurrent Protection Delay | 10s ± 3s |
| Secondary Discharge Overcurrent Protection Current Value | 660A ± 160A |
| Secondary Discharge Overcurrent Protection Delay | 320ms ± 150ms |
| Overcurrent Discharge Release | Automatic Recovery After a Delay of 32s ± 7s |
| Short Circuit Protection Value | 2,000 ± 500A |
| Short Circuit Protection Delay Time | 560μs to 960μs |
| Short Circuit Protection Recovery | Recovery by Releasing Load After Approximately 5s ± 2s |
| Discharge High Temperature Protection Value | 149°F ± 9°F / 65°C ± 5°C |
| Discharge High Temperature Protection Release Value | 140°F ± 9°F / 60°C ± 5°C |
| Discharge Low Temperature Protection Value | -4°F ± 9°F / -20°C ± 5°C |
| Discharge Low Temperature Protection Release Value | 14°F ± 9°F / -10°C ± 5°C |
| Charging High Temperature Protection Value | 131°F ± 9°F / 55°C ± 5°C |
| Charging High Temperature Protection Release Value | 122°F ± 9°F / 50°C ± 5°C |
| Charging Low Temperature Protection Value | 41°F ± 9°F / 5°C ± 5°C |
| Charging Low Temperature Protection Release Value | 50°F ± 9°F / 10°C ± 5°C |
| FET (Built-In) High Temperature Protection Value | 212°F to 230°F / 100°C to 110°C |
| FET (Built-In) High Temperature Protection Release Value | 176°F to 194°F / 80°C to 90°C |
| Equalizing Opening Voltage | 3.45V ± 0.05V |
| Equalize the Opening Pressure Difference | 15mV |
| Min Balance Current | 40mA |
| Max Balance Current | 100mA |
| Operation Temperature | -4°F to 167°F / -20°C to 75°C |
| Storage Temperature | 23°F to 104°F / -5°C to 40°C (Humidity Below 70%, Time ≤ 1 Year) |
| Heat the Opening Temperature | ≤41°F / 5°C |
| Heating Opening Conditions | Charge |
| Heating and Closing Conditions | Disconnect the Charger or Temperature ≥50°F / 10°C |
| Heating Power | 100W |
| Certifications | |
| FC, ETL, ANSI/CAN/UL 1973 | Yes |